The Response of Evidential Breath Alcohol Testing Instruments with Subjects Exposed to Organic Solvents and Gases: II. White Spirit and Nonane
Authors: Gill, R., Warner, H.E., Broster, C.G., Osselton, M.D., Ramsey, J.D., Wilson, H.K. and Wilcox, A.H.
Journal: Medicine, Science and the Law
Volume: 31
Issue: 3
Pages: 201-213
eISSN: 2042-1818
ISSN: 0025-8024
DOI: 10.1177/002580249103100303
Abstract:Following exposure to white spirit vapour, the effect of the expired solvent on evidential breath alcohol equipment was investigated under controlled exposure chamber conditions and in a simulated painting exercise. Five volunteers inhaled the solvent in an exposure chamber at a concentration of 100ppm for periods up to 4h 17min. Two other volunteers were exposed to white spirit while painting with domestic gloss paint in an un ventilated room under which conditions exposure concentrations reached 185ppm for 20min. Following all white spirit exposures, volunteers underwent breath tests with the Lion Intoximeter 3000. In all instances the apparent alcohol responses were very small and never exceeded a reading of 1 μg/100ml for breath samples more than 10min post-exposure. Simultaneous analytical work was conducted to demonstrate that white spirit was absorbed during exposure and was present in the breath and blood after the volunteers had left the exposure atmospheres. A further study involved the exposure of a volunteer to nonane vapour at 100ppm, demonstrating that this compound, being one of the principal components of white spirit, appears to be a good model for studying the uptake and elimination of white spirit. © 1991, The British Academy of Forensic Sciences. All rights reserved.
Source: Scopus
The response of evidential breath alcohol testing instruments with subjects exposed to organic solvents and gases. II. White spirit and nonane.
Authors: Gill, R., Warner, H.E., Broster, C.G., Osselton, M.D., Ramsey, J.D., Wilson, H.K. and Wilcox, A.H.
Journal: Med Sci Law
Volume: 31
Issue: 3
Pages: 201-213
ISSN: 0025-8024
DOI: 10.1177/002580249103100303
Abstract:Following exposure to white spirit vapour, the effect of the expired solvent on evidential breath alcohol equipment was investigated under controlled exposure chamber conditions and in a simulated painting exercise. Five volunteers inhaled the solvent in an exposure chamber at a concentration of 100ppm for periods up to 4h 17min. Two other volunteers were exposed to white spirit while painting with domestic gloss paint in an unventilated room under which conditions exposure concentrations reached 185ppm for 20min. Following all white spirit exposures, volunteers underwent breath tests with the Lion Intoximeter 3000. In all instances the apparent alcohol responses were very small and never exceeded a reading of 1 microgram/100ml for breath samples more than 10min post-exposure. Simultaneous analytical work was conducted to demonstrate that white spirit was absorbed during exposure and was present in the breath and blood after the volunteers had left the exposure atmospheres. A further study involved the exposure of a volunteer to nonane vapour at 100ppm, demonstrating that this compound, being one of the principal components of white spirit, appears to be a good model for studying the uptake and elimination of white spirit.
Source: PubMed
Preferred by: David Osselton
The response of evidential breath alcohol testing instruments with subjects exposed to organic solvents and gases. II. White spirit and nonane.
Authors: Gill, R., Warner, H.E., Broster, C.G., Osselton, M.D., Ramsey, J.D., Wilson, H.K. and Wilcox, A.H.
Journal: Medicine, science, and the law
Volume: 31
Issue: 3
Pages: 201-213
eISSN: 2042-1818
ISSN: 0025-8024
DOI: 10.1177/002580249103100303
Abstract:Following exposure to white spirit vapour, the effect of the expired solvent on evidential breath alcohol equipment was investigated under controlled exposure chamber conditions and in a simulated painting exercise. Five volunteers inhaled the solvent in an exposure chamber at a concentration of 100ppm for periods up to 4h 17min. Two other volunteers were exposed to white spirit while painting with domestic gloss paint in an unventilated room under which conditions exposure concentrations reached 185ppm for 20min. Following all white spirit exposures, volunteers underwent breath tests with the Lion Intoximeter 3000. In all instances the apparent alcohol responses were very small and never exceeded a reading of 1 microgram/100ml for breath samples more than 10min post-exposure. Simultaneous analytical work was conducted to demonstrate that white spirit was absorbed during exposure and was present in the breath and blood after the volunteers had left the exposure atmospheres. A further study involved the exposure of a volunteer to nonane vapour at 100ppm, demonstrating that this compound, being one of the principal components of white spirit, appears to be a good model for studying the uptake and elimination of white spirit.
Source: Europe PubMed Central