Synchrotron X-ray microbeam diffraction measurements of full elastic long range internal strain and stress tensors in commercial-purity aluminum processed by multiple passes of equal-channel angular pressing
Authors: Phan, T.Q., Levine, L.E., Lee, I.F., Xu, R., Tischler, J.Z., Huang, Y., Langdon, T.G. and Kassner, M.E.
Journal: Acta Materialia
Volume: 112
Pages: 231-241
ISSN: 1359-6454
DOI: 10.1016/j.actamat.2016.04.035
Abstract:Synchrotron X-ray microbeam diffraction was used to measure the full elastic long range internal strain and stress tensors of low dislocation density regions within the submicrometer grain/subgrain structure of equal-channel angular pressed (ECAP) aluminum alloy AA1050 after 1, 2, and 8 passes using route BC. This is the first time that full tensors were measured in plastically deformed metals at this length scale. The maximum (most tensile or least compressive) principal elastic strain directions for the unloaded 1 pass sample for the grain/subgrain interiors align well with the pressing direction, and are more random for the 2 and 8 pass samples. The measurements reported here indicate that the local stresses and strains become increasingly isotropic (homogenized) with increasing ECAP passes using route BC. The average maximum (in magnitude) LRISs are -0.43 σa for 1 pass, -0.44 σa for 2 pass, and 0.14 σa for the 8 pass sample. These LRISs are larger than those reported previously because those earlier measurements were unable to measure the full stress tensor. Significantly, the measured stresses are inconsistent with the two-component composite model.
Source: Scopus
Synchrotron X-Ray Microbeam Diffraction Measurements of Full Elastic Long Range Internal Strain and Stress Tensors in Commercial-Purity Aluminum Processed by Multiple Passes of Equal-Channel Angular Pressing.
Authors: Phan, T.Q., Levine, L.E., Lee, I.-F., Tischler, J.Z., Xu, R., Huang, Y., Langdon, T.G. and Kassner, M.E.
Journal: Acta Mater
Volume: 112
ISSN: 1359-6454
DOI: 10.1016/j.actamat.2016.04.035
Abstract:Synchrotron X-ray microbeam diffraction was used to measure the full elastic long range internal strain and stress tensors of low dislocation density regions within the submicrometer grain/subgrain structure of equal-channel angular pressed (ECAP) AA1050 after 1, 2, and 8 passes. This is the first time that full tensors were measured in plastically deformed metals at this length scale. This work supplements previous studies that measured long range internal stresses (LRIS) in ECAP AA1050 of multiple passes, but only for a single direction. The maximum (most tensile or least compressive) principal elastic strain directions for the unloaded 1 pass sample for the grain/subgrain interiors align well with the pressing direction, and are more random for the 2 and 8 pass samples. The measurements reported here indicate that the local stresses and strains become increasingly isotropic (homogenized) with increasing ECAP passes using route BC. The average maximum (in magnitude) LRISs are -0.43 σa for 1 pass, -0.44 σa for 2 pass, and 0.14 σa for the 8 pass sample. These LRISs appear to be larger than LRISs reported by previous works (using single reflection measurements).
Source: PubMed
Synchrotron X-ray microbeam diffraction measurements of full elastic long range internal strain and stress tensors in commercial-purity aluminum processed by multiple passes of equal-channel angular pressing.
Authors: Phan, T.Q., Levine, L.E., Lee, I.-F., Xu, R., Tischler, J.Z., Huang, Y., Langdon, T.G. and Kassner, M.E.
Journal: ACTA MATERIALIA
Volume: 112
Pages: 231-241
eISSN: 1873-2453
ISSN: 1359-6454
DOI: 10.1016/j.actamat.2016.04.035
Source: Web of Science (Lite)
Synchrotron X-Ray Microbeam Diffraction Measurements of Full Elastic Long Range Internal Strain and Stress Tensors in Commercial-Purity Aluminum Processed by Multiple Passes of Equal-Channel Angular Pressing.
Authors: Phan, T.Q., Levine, L.E., Lee, I.-F., Tischler, J.Z., Xu, R., Huang, Y., Langdon, T.G. and Kassner, M.E.
Journal: Acta materialia
Volume: 112
ISSN: 1359-6454
DOI: 10.1016/j.actamat.2016.04.035
Abstract:Synchrotron X-ray microbeam diffraction was used to measure the full elastic long range internal strain and stress tensors of low dislocation density regions within the submicrometer grain/subgrain structure of equal-channel angular pressed (ECAP) AA1050 after 1, 2, and 8 passes. This is the first time that full tensors were measured in plastically deformed metals at this length scale. This work supplements previous studies that measured long range internal stresses (LRIS) in ECAP AA1050 of multiple passes, but only for a single direction. The maximum (most tensile or least compressive) principal elastic strain directions for the unloaded 1 pass sample for the grain/subgrain interiors align well with the pressing direction, and are more random for the 2 and 8 pass samples. The measurements reported here indicate that the local stresses and strains become increasingly isotropic (homogenized) with increasing ECAP passes using route BC. The average maximum (in magnitude) LRISs are -0.43 σa for 1 pass, -0.44 σa for 2 pass, and 0.14 σa for the 8 pass sample. These LRISs appear to be larger than LRISs reported by previous works (using single reflection measurements).
Source: Europe PubMed Central